More Details

PHYSICAL PROPERTIES:

Flexural Strength: 130 Mpa

Vickers Hardness: 62 HvWear

Resistance: 0.52 wt%Filler

Load: 83.3 wt%

Depth of Cure: 5.9 mm

Radiopacity:  3.4 Al :

mmFluoride Release & Recharge: Yes

 



Cleaning of tooth surface - Thoroughly clean the tooth surface to remove plaque.


  • Shade selection - Select appropriate shade using a shade guide while the tooth is still moist.
  • Cavity preparation - Prepare the cavity following the conventional method.
  • Isolation - Isolate with a rubber dam
  • Pulp protection - In the case where the pulp is exposed or the affected area is close to the pulp, cap the pulp with calcium hydroxide.
  • Conditioning and application of adhesive - Apply dentin adhesive following the manufacturer’s instructions for use.
  • Placement - Dispense adequate amount of BEAUTIFIL II onto a paper pad from the syringe. Apply the dispensed material into the cavity using a suitable instrument
  • and create the shape desired. 
  • Light-curing - Light-cure using a dental light-curing unit. Using halogen curing light 20 sec curing time is sufficient and using LED curing light 10 sec curing time is sufficient. 

" Finishing and polishing - After light-curing, contour, finish and polish the restoration following the conventional method.